lsfabric out active/inactive issue with EMC VNX Series

Hi ,
We found that SVC do not understand EMC VNX fabric active or inactive, after long time IBM developers find out the issue and they will fix it.
VM
APAR IC80749:
ERROR DESCRIPTION:
On controllers (for example EMC Clariion) that have fibre
channel logins as both target and initiator the active/inactive
state may be incorrectly displayed.
The reason is that both the target logins (which are being used)
and the initiator logins (which are not) may update the status.
Hence the status may be shown as “inactive” becuase the
initiator logins are not active, while the target ones are in
fact being used.
CMVC 142997 is tracking this.
LOCAL FIX:
No local fix or workaround.